Skip to main content
Login | Suomeksi | På svenska | In English

A Study on Whole Blood Cryopreservation for Immunophenotyping by Flow Cytometry and Its Application on COVID-19 Research

Show simple item record

dc.date.accessioned 2021-12-14T14:14:37Z
dc.date.available 2021-12-14T14:14:37Z
dc.date.issued 2021-12-14
dc.identifier.uri http://hdl.handle.net/123456789/38823
dc.title A Study on Whole Blood Cryopreservation for Immunophenotyping by Flow Cytometry and Its Application on COVID-19 Research en
ethesis.faculty Lääketieteellinen tiedekunta fi
ethesis.faculty Faculty of Medicine en
ethesis.faculty Medicinska fakulteten sv
ethesis.faculty.URI http://data.hulib.helsinki.fi/id/a4d5aaa2-b5aa-41a7-ba4c-e5e0df7a902d
ethesis.university.URI http://data.hulib.helsinki.fi/id/50ae46d8-7ba9-4821-877c-c994c78b0d97
ethesis.university Helsingin yliopisto fi
ethesis.university University of Helsinki en
ethesis.university Helsingfors universitet sv
dct.creator Nguyen, Ngoc Anh
dct.issued 2019
dct.abstract Immunophenotyping by flow cytometry (FC) is an established practice to identify immune cells and their cellular changes at the single-cell level. Since preserving the structural integrity of cellular epitopes is vital for immunophenotyping, samples should be processed shortly after being collected. However, the requirements of complex facilities and trained personnel for flow cytometry make it challenging to handle samples immediately. Fixation and cryopreservation extend sample shelf life and allow analysing longitudinal samples simultaneously while minimizing technical variation. Nevertheless, usage of whole blood cryopreservation in flow cytometry is limited due to challenges in preserving epitope structures during fixation and detecting dim antigens. This thesis investigates the performances of four commercial whole blood cryopreserving kits; 1) Cytodelics, 2) Stable-Lyse V2 and Stable-Store V2 (SLSS-V2), 3) Proteomic stabiliser (PROT-1), and 4) Transfix. Peripheral blood samples were processed with these stabilising buffers immediately after the collection and cryopreserved until further analysis by flow cytometry. Here, we measured the stability of major immune lineages, T cell subpopulations, and activated neutrophil profiles in samples treated with these commercial whole blood stabilisers. Our flow cytometry data showed that PROT-1, Transfix and Cytodelics maintained the distribution of major leukocyte subsets – granulocytes, T cells, natural killer cells and B cells, comparable to unpreserved samples despite the attenuation of fluorescence intensities. Moreover, these three stabilisers also preserved phenotypes of activated neutrophils upon stimulation with N-Formylmethionyl-leucyl-phenylalanine and Lipopolysaccharides. The upregulation of adhesion molecules (CD11b), Fc receptors (CD16) and granule proteins (CD66b) as well as the shedding of surface L-selectin (CD62L) on activated neutrophils was conserved most efficiently in PROT-1, followed by Cytodelics. On the other hand, none of the stabilisers provided a reliable detection of CCR7 for accurate quantification of T cell subpopulations. COVID-19 is caused by a highly transmissible and pathogenic coronavirus, so-called severe acute respiratory syndrome coronavirus 2 (SARS-COV-2). To test the potential of whole blood cryopreservation kits for flow cytometry in COVID-19 research, we studied the detectability of major leukocyte lineages and granulocyte subsets in longitudinal patient samples processed with Cytodelics. High dimensional analysis with Uniform Manifold Approximation and Projection (UMAP) and Self-Organising Maps (FlowSOM) clustering revealed remarkable stability of CD3, CD15, and CD14 expression in samples stored with Cytodelics. It allowed the detection of lymphopenia and emergency granulopoiesis often found during the acute phase of severe SARS-COV-2 infection. Nonetheless, we could not determine signatures of granulocyte subsets, notably suppressive neutrophils, during the acute and convalescent phases of COVID-19. Variable detection of lowly expressed markers and diminished fluorescence intensities in Cytodelics - preserved samples might have hindered the analysis. In conclusion, this study demonstrates that PROT-1, Transfix, and Cytodelics enabled reliable detection of highly expressed leukocyte markers, whereas SLSS-V2 preservation resulted in the most inaccurate identification of studied markers. Notably, our results show that Cytodelics can be applied in COVID-19 studies to immunophenotype major immune lineages by flow cytometry. Nevertheless, more optimisation is needed for less abundant or fixation-sensitive epitopes to enhance the efficacy of whole blood cryopreservation for flow cytometry. en
dct.subject Cryopreservation
dct.subject Immunophenotyping
dct.subject Flow Cytometry
dct.subject Immune lineages
dct.subject Lymphocytes
dct.subject Granulocytes
dct.subject COVID-19
dct.subject suppressive neutrophils
ethesis.language.URI http://data.hulib.helsinki.fi/id/languages/eng
ethesis.language englanti fi
ethesis.language English en
ethesis.language engelska sv
ethesis.supervisor MD. PhD Santtu Heinonen and Dr. Eliisa Kekäläinen und
ethesis.thesistype pro gradu -tutkielmat fi
ethesis.thesistype master's thesis en
ethesis.thesistype pro gradu-avhandlingar sv
ethesis.thesistype.URI http://data.hulib.helsinki.fi/id/thesistypes/mastersthesis
dct.identifier.ethesis E-thesisID:9562cd32-a4c2-426f-acd2-7307dc840268
ethesis-internal.timestamp.reviewStep 2021-11-04 11:41:46:162
dct.identifier.urn URN:NBN:fi:hulib-202112144259
ethesis.discipline.med Immunology und
ethesis.facultystudyline Cross-disciplinary translational medicine fi
ethesis.facultystudyline Cross-disciplinary translational medicine en
ethesis.facultystudyline Cross-disciplinary translational medicine sv
ethesis.facultystudyline.URI http://data.hulib.helsinki.fi/id/SH_TMED-510
ethesis.mastersdegreeprogram Translationaalisen lääketieteen maisteriohjelma (Translational Medicine) fi
ethesis.mastersdegreeprogram Master's Programme in Translational Medicine en
ethesis.mastersdegreeprogram Magisterprogrammet i translationell medicin sv
ethesis.mastersdegreeprogram.URI http://data.hulib.helsinki.fi/id/MH30_002

Files in this item

Files Size Format View
Nguyen_Ngoc Anh_Thesis_2021.pdf 2.242Mb PDF

This item appears in the following Collection(s)

Show simple item record