Skip to main content
Login | Suomeksi | På svenska | In English

Browsing by Subject "outdoor air"

Sort by: Order: Results:

  • Heiskanen, Ilmari (2021)
    Interest towards indoor air quality has increased for several decades from human health perspective. In order to evaluate the quality of indoor air in terms of volatile organic compound (VOC) levels, robust analytical procedures and techniques must be used for indoor air VOC measurements. Since indoor building materials are the greatest source of indoor VOC emissions, same kind of procedures must be used for analysis of emission rates from building materials and their surfaces. Theory part of this thesis reviews background of VOCs and human health, legislation and guideline values, common building materials with emissions and used sampling techniques/approaches for indoor air sampling and surface material emission rate sampling & analysis. Discussed sampling techniques include, for example, material emission test chambers, field and laboratory test emission cells, solid phase microextraction (SPME) fibre applications and Radiello passive samplers. Also new innovative approaches are discussed. Used common analysis instruments are Gas Chromatography (GC) with Mass Spectrometer (MS) or Flame Ionization Detector (FID) for VOCs and High-Performance Liquid Chromatography-Ultraviolet/Visible light detector (HPLC-UV/VIS) for carbonyl VOCs (e.g. formaldehyde) after suitable derivatization. Analytical procedures remain highly ISO 16000 standard series orientated even in recent studies. In addition, potential usage of new modern miniaturized sample collection devices SPME Arrow and In-tube extraction (ITEX) used in experimental part of this thesis are discussed as an addition to indoor air and VOC emission studies. The aim of the experimental part of this thesis was to develop calibrations for selected organic nitrogen compounds with SPME Arrow and ITEX sampling techniques and test the calibration with indoor and outdoor samples. A calibration was successfully carried out with SPME Arrow (MCM-41 sorbent), ITEX (MCM-TP sorbent) and ITEX (Polyacrylonitrile (PAN) 10 % sorbent) with permeation system combined with GC-MS for the following selected organic nitrogen compounds: triethylamine, pyridine, isobutyl amine, allylamine, trimethylamine, ethylenediamine, dipropyl amine, hexylamine, 1,3-diaminopropane, 1-methyl-imidazole, N, N-dimethylformamide, 1,2-diaminocyclohexane, 1-nitropropane and formamide. The overall quality of the calibration curves was evaluated, and the calibrations were compared in terms of linear range, relative standard deviation (RSD) % for accepted calibration levels and obtained Limits of Detection (LOD) values. Also, ways to improve the calibrations were discussed. The calibration curves were tested with real indoor and outdoor samples and quantitative, as well as semi-quantitative, results were obtained.